I don t believe that it s connected to any other outside vents.
Aav vent in attic.
Aavs in attics should be at least six inches above the attic insulation.
More product details.
Aav vent terminates in attic.
Automatic air vents are no longer approved and should be replaced.
Device and aavs on the branches.
When an aav is installed in an attic make sure that it s at least 6 inches above insulation any less and there s a good chance insulation will be drawn into the unit severely affecting performance.
Aav s have to be readily accessible not sure if the ahj will consider them accessible while in the attic.
Seriously though i can t think of any application where in a dw vent may be terminated in an attic space.
The attic has certain conditions that can affect the aav performance which should be considered before choosing this as a location.
X 2 pvc air admittance valve features a 1 way valve that permits air to enter when negative pressures develop in the piping system.
A plumber would probably know the answer to the vent issue but would he know or.
Depending on the valve and the size of the vent aavs can support one or multiple vent lines.
Only teflon tape can be used on the valves threads.
Prevents sewer gases from escaping into a building.
Then gravity closes the valve keeping sewer gases out of the room.
I have read that it s allowed in some cases.
To ensure proper operation of your aav make sure that the surrounding area is free of obstructions and things that can knock against it.
This vent is for a master bath addition 3 drain vent.
These valves are gravity operated devices that respond to the negative pressure of draining water and open to let air in.
Some authorities recommend air admittance valves on kitchen island fixtures to reduce the risk of horizontal vent lines becoming obstructed.
The relief vent must connect to the vent stack stack vent or extend outdoors to the open air unless it is used in conjunction with a stack that is connected to a p a p a.
The oatey sure vent 1 1 2 in.
Closes by gravity to seal the vent terminal at zero differential pressure.
The attic has certain conditions that can affect the aav performance which should be considered before choosing this as a location.
The relief vent may also serve as a vent for the fixture.
The temperature ranges that the sure vent will operate in are 40 f to 150 f your attic can experience drastic temperature variations depending on how it is vented and your geographic location.
The drain waste vent system dwv employs a mechanical vent also known as an air admittance valve or aav.
The irc allows them on a waste stack that terminates in an attic as long as the aav is 6 inches above the insulation.
This application may have been approved by this local jurisdiction however you should be aware that this type of system is not recognized by california building officials as an approved vent system.
One solution is an air admittance valve or aav.
X 2 the oatey sure vent 1 1 2 in.
Call a licensed plumber to fix the problem.